catalog

КМВеВнг-LS (JE-LiYCY-LS) 2 class of flexibility Control and data transmission cables, shielded

КМВеВнг-LS (JE-LiYCY-LS) 2 class of flexibility
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

FIELD OF APPLICATION

  • Construction, energy, industrial and transportation facilities
  • Data transmission in signaling, instrumentation and control systems, automated control systems, monitoring and special applications
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • Flexible
  • The cables are tested for laying outside the hermetic zone in cable structures and premises of NPPs, in systems of classes 3, 4 according to NP 306.2.141-2008
  • The presence of a shield protects against electromagnetic waves
  • Additional versions: oil-resistant, armored

CONSTRUCTION

Resin

Copper stranded conductors in accordance with the requirements of DSTU EN 60228, flexibility class 2

Insulation

polyvinyl chloride plastic of reduced fire hazard

Outer shell

black polyvinyl chloride plastic with low smoke and gas emission

Number of cores

1÷61

Screen

Copper wire braid

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,2
110

0,28
67

0,5
36

0,75
24,5

1,0
18,1

1,5
12,1

2,5
7,41

Temperature range

-40˚C to +70˚C

Test voltage

2000 V (2.5 mm2 - 2500 V)

Operating voltage

300/500 W

Electrical resistance of insulation

10 MOhm/km

Minimum bending radius

7,5 х D

Color identification of cores

DSTU IEC 60189-2, DIN 47100

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809

Smoke smoke - clause 4.4 of DSTU 4809

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2

Halogens and corrosive activity - clause 4.6 of DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10403701 2х0,5 9.6 32.78 120
10403702 2х0,75 10.0 39.41 134
10403703 2х1 10.3 45.09 144
10403704 2х1,5 11.6 57.24 171
10403705 2х2,5 13.3 79,05 208
10403706 3х0,5 10.0 38.50 133
10403707 3х0,75 10.4 47.57 151
10403708 3х1 11.0 55.62 163
10403709 3х1,5 12.1 72.30 199
10403710 3х2,5 14.0 103.33 247
10403711 4х0,5 10.7 45.07 149
10403712 4х0,75 11.3 56.69 171
10403713 4х1 11.7 67.16 187
10403714 4х1,5 13.2 88.57 231
10403715 4х2,5 15.5 129.05 292
10403716 5х0,5 11.6 52.66 168
10403717 5х0,75 12.1 66.07 193
10403718 5х1 12.8 80.58 215
10403719 5х1,5 14.7 120.77 283
10403720 5х2,5 17.2 159.05 344
10403721 6х0,5 12.4 58.87 185
10403722 6х0,75 13.1 75.74 215
10403723 6х1 13.6 91.18 238
10403724 6х1,5 15.7 122.29 299
10403725 6х2,5 18.7 182.85 395
10403726 7х0,5 13.5 63.46 193
10403727 7х0,75 14.3 82.63 227
10403728 7х1 15.1 100.37 252
10403729 7х1,5 17.4 235.75 320
10403730 7х2,5 20.3 205.29 426
10403731 12х0,5 16.5 95.8 273
10403732 12х0,75 17.2 127.91 326
10403733 12х1 18.1 158.83 376
10403734 12х1,5 20.5 218.18 486
10403735 12х2,5 24.4 335.14 668
10403736 18х0,5 18.6 130.95 359
10403737 18х0,75 19.9 177.85 435
10403738 18х1 20.8 223.70 495
10403739 18х1,5 24.1 309.16 671
10403740 18х2,5 28.5 482.96 919
10403741 27х0,5 22.1 182.76 476
10403742 27х0,75 23.7 262.33 604
10403743 27х1 24.7 319.78 703
10403744 27х1,5 28.6 448.63 956
10403745 27х2,5 34.5 723.96 1340
10403746 36х0,5 24.7 223.08 604
10403747 36х0,75 26.2 326.22 758
10403748 36х1 27.6 415.25 875
10403749 36х1,5 32.5 586.39 1200
10403750 36х2,5 38.5 967.15 1696

similar products