catalog

КМНЕНнг-HF (JE-LiH(St)НU-PF) 2 class of flexibility Control and data cables, shielded, twisted pair

КМНЕНнг-HF (JE-LiH(St)НU-PF) 2 class of flexibility
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

FIELD OF APPLICATION

  • Construction, energy, industrial and transportation facilities
  • Data transmission in signaling, instrumentation and control systems, automated control systems, monitoring and special applications
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • Flexible
  • The cables are tested for laying outside the hermetic zone in cable structures and premises of NPPs, in systems of classes 3, 4 according to NP 306.2.141-2008
  • The presence of a shield protects against electromagnetic waves
  • Additional versions: oil-resistant, armored

CONSTRUCTION

Resin

Copper stranded conductors in accordance with the requirements of DSTU EN 60228, flexibility class 2

Insulation

halogen-free composition

Outer shell

halogen-free red composition

Number of cores

1÷61х2

Screen

synthetic film foiled with aluminum + grounding conductor

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,2
110

0,28
67

0,5
36

0,75
24,5

1,0
18,1

1,5
12,1

2,5
7,41

Temperature range

-40˚C to +70˚C

Test voltage

2000 V (2.5 mm2 - 2500 V)

Operating voltage

300/500 W

Electrical resistance of insulation

10 MOhm/km

Minimum bending radius

7,5 х D

Color identification of cores

DSTU IEC 60189-2, DIN 47100

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809

Smoke smoke - clause 4.4 of DSTU 4809

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2

Halogens and corrosive activity - clause 4.6 of DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10430201 1х2х0,2 5.0 4.8 40
10430202 2х2х0,2 8.0 8.49 77
10430204 4х2х0,2 8.7 15.86 121
10430205 5х2х0,2 9.8 19.45 149
10430216 1х2х0,5 7.2 10.33 32
10430217 2х2х0,5 11.8 19.54 63
10430219 4х2х0,5 12.7 37.97 110
10430220 5х2х0,5 14.3 47.18 135
10430223 1х2х0,75 7.4 14.94 34
10430224 2х2х0,75 13.3 28.76 67
10430226 4х2х0,75 14.4 56.39 118
10430227 5х2х0,75 16.3 70.21 146
10430237 1х2х1,5 9.5 28.62 74
104302388 2х2х1,5 16.2 56.12 140
10430240 4х2х1,5 17.8 111.12 248
10430241 5х2х1,5 20.4 138.62 308
10430244 1х2х2,5 11.1 46.95 106
10430245 2х2х2,5 19.4 92.79 203
10430247 4х2х2,5 21.8 184.46 365
10430248 5х2х2,5 24.6 230.29 452