POWERMATIC® YSLYSY-O 0,6/1kV without a grounding wire Power cable 0.6/1.0 kV flexible, armored
Stability during single burning
FIELD OF APPLICATION
- Production of industrial machinery, heating and air conditioning equipment
- In residential, household, administrative, industrial and other premises, if the cable is not subject to mechanical damage during operation
- For electrical machines with alternating current
- For fixed installation in distribution networks and industrial installations
- For stationary applications as well as for installation with limited mobility and no tensile loads
- In dry and wet production facilities, canals, tunnels, and on special cable racks
ADVANTAGES
- Easy installation due to great flexibility
- The presence of armor provides protection against external mechanical and electrical influences and, in some cases, protection against tensile loads.
CONSTRUCTION
|
Resin |
Copper conductors in accordance with the requirements of DSTU EN 60228, flexibility class 5 |
|
Insulation |
Polyvinyl chloride plastic |
|
Outer shell |
Polyvinyl chloride plastic, black color |
|
Number of cores |
2, 3, 4, 5, 7, 12, 18, 25 |
|
Inner shell |
Polyvinyl chloride plastic |
|
Armor |
Steel wire braid |
TECHNICAL CHARACTERISTICS
Electrical resistance depending on the rated area cross-section of the conductor, not more:
mm²
Ohm/km
0,75
26
1
19,5
1,5
13,3
2,5
7,98
4
4,95
6
3,3
10
1,91
16
1,21
25
0,78
36
0,554
|
Temperature range |
from -40˚С to +70˚С from -5˚С to +70˚С |
|
Temperature range: |
from -40˚С to +70˚С |
|
Test voltage |
4000 W |
|
Operating voltage |
600/1000 W |
|
Electrical resistance of insulation |
100 megohms/km |
|
Minimum bending radius |
20 х D 6 х D |
|
Minimum bending radius limited mobility fixed application |
20 х D |
|
Color identification of cores |
EN 50334 DSTU HD 308 S2 |
COMPLIANCE / STANDARDS
Easy installation due to great flexibility
The presence of armor provides protection against external mechanical and electrical influences and, in some cases, protection against tensile loads.
TABLE OF NOMENCLATURES
| Article no. | Number of cores and cross section mm2 |
Maximum outer diameter |
Mass of copper | Mass. |
|---|---|---|---|---|
| 20101001 | 2х0,75 | 12.7 | 14.1 | 160 |
| 20101002 | 3х0,75 | 13.2 | 21.1 | 175 |
| 20101003 | 4х0,75 | 14.0 | 28.1 | 198 |
| 20101004 | 5х0,75 | 14.9 | 35.1 | 226 |
| 20101005 | 7х0,75 | 16.1 | 49.2 | 269 |
| 20101006 | 12х0,75 | 19.9 | 84.3 | 404 |
| 20101007 | 18х0,75 | 22.8 | 126.5 | 544 |
| 20101008 | 25х0,75 | 26.6 | 175.7 | 715 |
| 20101009 | 2х1 | 13.1 | 18.7 | 171 |
| 20101010 | 3х1 | 13.5 | 28.1 | 189 |
| 20101011 | 4х1 | 14.4 | 37.5 | 216 |
| 20101012 | 5х1 | 15.6 | 46.9 | 254 |
| 20101013 | 7х1 | 16.6 | 65.6 | 296 |
| 20101014 | 12х1 | 20.6 | 112.5 | 450 |
| 20101015 | 18х1 | 23.6 | 168.7 | 610 |
| 20101016 | 25х1 | 27.7 | 234.3 | 806 |
| 20101017 | 2х1,5 | 14.2 | 27.5 | 205 |
| 20101018 | 3х1,5 | 14.7 | 41.2 | 229 |
| 20101019 | 4х1,5 | 16.0 | 54.9 | 270 |
| 20101020 | 5х1,5 | 17.1 | 68.6 | 313 |
| 20101021 | 7х1,5 | 18.2 | 96.1 | 369 |
| 20101022 | 12х1,5 | 23.1 | 164.7 | 581 |
| 20101023 | 18х1,5 | 26.7 | 247.1 | 796 |
| 20101024 | 25х1,5 | 31.3 | 343.2 | 1059 |
| 20101025 | 3х2,5 | 16.3 | 68.6 | 291 |
| 20101026 | 4х2,5 | 17.4 | 91.5 | 339 |
| 20101027 | 5х2,5 | 18.7 | 114.4 | 397 |
| 20101028 | 7х2,5 | 20.3 | 160.1 | 485 |
| 20101029 | 12х2,5 | 25.6 | 274.5 | 760 |
| 20101030 | 4х4 | 20.3 | 147.6 | 474 |
| 20101031 | 5х4 | 21.9 | 184.5 | 562 |
| 20101032 | 7х4 | 23.8 | 258.3 | 693 |
| 20101033 | 4х6 | 22.0 | 221.4 | 593 |
| 20101034 | 5х6 | 24.1 | 276.7 | 717 |
| 20101035 | 4х10 | 25.0 | 374.8 | 829 |
| 20101036 | 5х10 | 27.4 | 468.6 | 1009 |
| 20101037 | 4х16 | 28.3 | 599.7 | 1149 |
| 20101038 | 5х16 | 31.0 | 749.7 | 1406 |
| 20101039 | 4х25 | 39.1 | 937.1 | 1892 |
| 20101040 | 4х35 | 42.5 | 1311.9 | 2403 |