catalog

POWERMATIC® YSLYSY-J 0,6/1kV with w/e conductive grounding Power cable 0.6/1.0 kV flexible, armored

POWERMATIC® YSLYSY-J 0,6/1kV with w/e conductive grounding
icon_red_1

Stability during single burning

FIELD OF APPLICATION

  • Production of industrial machinery, heating and air conditioning equipment
  • In residential, household, administrative, industrial and other premises, if the cable is not subject to mechanical damage during operation
  • For electrical machines with alternating current
  • For fixed installation in distribution networks and industrial installations
  • For stationary applications as well as for installation with limited mobility and no tensile loads
  • In dry and wet production facilities, canals, tunnels, and on special cable racks

ADVANTAGES

  • Easy installation due to great flexibility
  • The presence of armor provides protection against external mechanical and electrical influences and, in some cases, protection against tensile loads.

CONSTRUCTION

Resin

Copper conductors in accordance with the requirements of DSTU EN 60228, flexibility class 5

Insulation

Polyvinyl chloride plastic.

Outer shell

Polyvinyl chloride plastic, black color

Number of cores

2, 3, 4, 5, 7, 12, 18, 25

Inner shell

Polyvinyl chloride plastic

Armor

Steel wire braid

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,75
26

1
19,5

1,5
13,3

2,5
7,98

4
4,95

6
3,3

10
1,91

16
1,21

25
0,78

35
0,554

Temperature range

from -40˚С to +70˚С from -5˚С to +70˚С

Temperature range:
-in fixed installation
-conditions during installation

from -40˚С to +70˚С
from -5°C to +70°C

Test voltage

4000 W

Operating voltage

600/1000 W

Electrical resistance of insulation

100 megohms/km

Minimum bending radius

20 х D 6 х D

Minimum bending radius limited mobility fixed application

20 х D
6 х D

Color identification of cores

EN 50334 DSTU HD 308 S2

COMPLIANCE / STANDARDS

Easy installation due to great flexibility

The presence of armor provides protection against external mechanical and electrical influences and, in some cases, protection against tensile loads.

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
20100901 2х0,75 12.7 14.1 160
20100902 3х0,75 13.2 21.1 175
20100903 4х0,75 14.0 28.1 198
20100904 5х0,75 14.9 35.1 226
20100905 7х0,75 16.1 49.2 269
20100906 12х0,75 19.9 84.3 404
20100907 18х0,75 22.8 126.5 544
20100908 25х0,75 26.6 175.7 715
20100909 2х1 13.1 18.7 171
20100910 3х1 13.5 28.1 189
20100911 4х1 14.4 37.5 216
20100912 5х1 15.6 46.9 254
20100913 7х1 16.6 65.6 296
20100914 12х1 20.6 112.5 450
20100915 18х1 23.6 168.7 610
20100916 25х1 27.7 234.3 806
20100917 2х1,5 14.2 27.5 205
20100918 3х1,5 14.7 41.2 229
20100919 4х1,5 16.0 54.9 270
20100920 5х1,5 17.1 68.6 313
20100921 7х1,5 18.2 96.1 369
20100922 12х1,5 23.1 164.7 581
20100923 18х1,5 26.7 247.1 796
20100924 25х1,5 31.3 343.2 1059
20100925 3х2,5 16.3 68.6 291
20100926 4х2,5 17.4 91.5 339
20100927 5х2,5 18.7 114.4 397
20100928 7х2,5 20.3 160.1 485
20100929 12х2,5 25.6 274.5 760
20100930 4х4 20.3 147.6 474
20100931 5х4 21.9 184.5 562
20100932 7х4 23.8 258.3 693
20100933 4х6 22.0 221.4 593
20100934 5х6 24.1 276.7 717
20100935 4х10 25.0 374.8 829
20100936 5х10 27.4 468.6 1009
20100937 4х16 28.3 599.7 1149
20100938 5х16 31.0 749.7 1406
20100939 4х25 39.1 937.1 1892
20100940 4х35 42.5 1311.9 2403