catalog

КОVЕVng-LS (J-Y(St)Y-LS-PF) Communication and alarm cable, shielded, twisted pair, flame retardant

КОVЕVng-LS (J-Y(St)Y-LS-PF)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • Alarm systems, access control systems, management, control, communication and telecommunication systems
  • For the transmission of low-power electrical signals
  • For installation of station equipment, for stationary installation inside buildings, structures, in dry and wet areas

ADVANTAGES

  • Shields protect against electromagnetic waves and absorb external electromagnetic signals
  • The wires have been tested for use outside the hermetic zone in cable structures of NPP premises, in systems of classes 3, 4 according to NP 306.2.141-2008
  • Additional versions: armoring, hydrophobicity, oil resistance

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

polyvinyl chloride plastic of reduced fire hazard

Outer shell

black polyvinyl chloride plastic with low smoke and gas emission

Number of cores

1÷61х2

Screen

synthetic film foiled with aluminum + grounding conductor

Screen 1

braid of copper ("el" - tinned) wires

Screen 2

shielded pairs

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

0,4
160

0,51
110

0,8
36

1,05
24,5

1,13
18,1

1,38
12,1

1,78
7,41

Temperature range

-30˚С to +70˚С

Test voltage

1500 W

Operating voltage

300 W

Electrical resistance of insulation

100 megohms/km

Minimum bending radius

10 х D

Color identification of cores

DSTU IEC 60189-2

Electrical capacity

100 pF/m

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Toxicity - clause 4.3 of DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosive activity - clause 4.6 of DSTU 4809. clause 4.6 of DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10308601 1х2х0,4 4.4 3,5 17
10308602 2х2х0,4 6.9 5,89 34
10308603 3х2х0,4 7.2 8,27 43
10308604 4х2х0,4 7.4 10,66 51
10308605 5х2х0,4 8.5 13,04 65
10308606 6х2х0,4 9.6 15,43 74
10308607 8х2х0,4 12.7 20,2 89
10308608 10х2х0,4 15.3 24,97 112
10308609 14х2х0,4 16.6 29,74 129
10308610 20х2х0,4 22.1 48,82 186
10308611 1х2х0,51 4.6 4,99 20
10308612 2х2х0,51 7.3 8,87 42
10308613 3х2х0,51 7.7 12,75 54
10308614 4х2х0,51 8.0 16,62 66
10308615 5х2х0,51 9.0 20,5 80
10308616 6х2х0,51 10.3 24,38 92
10308617 8х2х0,51 13.8 32,13 116
10308618 10х2х0,51 16.6 39,89 146
10308619 14х2х0,51 18.1 47,64 168
10308620 20х2х0,51 24.1 78,66 247
10308621 1х2х0,8 5.7 10,66 32
10308622 2х2х0,8 9.3 20,2 63
10308623 3х2х0,8 9.8 29,74 83
10308624 4х2х0,8 10.1 39,28 102
10308625 5х2х0,8 11.4 48,82 125
10308626 6х2х0,8 13.2 58,35 145
10308627 8х2х0,8 17.7 77,43 181
10308628 10х2х0,8 21.6 96,51 227
10308629 14х2х0,8 23.5 115,59 265
10308630 20х2х0,8 31.7 191,91 402
10308631 1х2х1,05 6.3 17,55 43
10308632 2х2х1,05 10.5 33,98 85
10308633 3х2х1,05 10.9 50,42 112
10308634 4х2х1,05 11.4 66,85 143
10308635 5х2х1,05 13.1 83,28 180
10308636 6х2х1,05 15.1 99,72 210
10308637 8х2х1,05 20.6 132,58 269
10308638 10х2х1,05 24.5 165,45 332
10308639 14х2х1,05 27.4 198,32 395
10308640 20х2х1,05 36.9 329,79 606
10308641 1х2х1,38 7.5 29,5 63
10308642 2х2х1,38 12.7 57,89 124
10308643 3х2х1,38 13.6 86,28 169
10308644 4х2х1,38 13.7 114,66 212
10308645 5х2х1,38 16.6 143,05 266
10308646 6х2х1,38 18.3 171,43 316
10308647 8х2х1,38 24.9 228,21 399
10308648 10х2х1,38 30.4 284,98 500
10308649 14х2х1,38 33.2 341,75 587
10308650 20х2х1,38 45.0 568,84 913