catalog

КОВелВнг-LS (J-YCY-LS-PF) Communication and signaling cable, shielded, twisted pair, with low smoke and gas emission

КОВелВнг-LS (J-YCY-LS-PF)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • Alarm systems, access control systems, management, control, communication and telecommunication systems
  • For the transmission of low-power electrical signals
  • For installation of station equipment, for stationary installation inside buildings, structures, in dry and wet areas

ADVANTAGES

  • Shields protect against electromagnetic waves and absorb external electromagnetic signals
  • The wires have been tested for use outside the hermetic zone in cable structures of NPP premises, in systems of classes 3, 4 according to NP 306.2.141-2008
  • Additional versions: armoring, hydrophobicity, oil resistance

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

polyvinyl chloride plastic of reduced fire hazard

Outer shell

black polyvinyl chloride plastic with low smoke and gas emission

Number of cores

1÷61х2

Screen

braid of copper ("el" - tinned) wires

Screen 2

shielded pairs

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

0,4
160

0,51
110

0,8
36

1,05
24,5

1,13
18,1

1,38
12,1

1,78
7,41

Temperature range

-30˚С to +70˚С

Test voltage

1500 W

Operating voltage

300 W

Electrical resistance of insulation

100 megohms/km

Minimum bending radius

10 х D

Color identification of cores

DSTU IEC 60189-2

Electrical capacity

100 pF/m

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosive activity - clause 4.6 of DSTU 4809. p.4.6 DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10308801 1х2х0,4 4.4 20.52 53
10308802 2х2х0,4 6.9 32.74 90
10308803 3х2х0,4 7.2 36.60 102
10308804 4х2х0,4 7.4 41.55 116
10308805 5х2х0,4 8.5 46.78 136
10308806 6х2х0,4 9.6 52.12 151
10308807 8х2х0,4 12.7 59.84 172
10308808 10х2х0,4 15.3 71.50 209
10308809 14х2х0,4 16.6 80.30 234
10308810 20х2х0,4 22.1 108.13 308
10308811 1х2х0,51 4.6 23.59 58
10308812 2х2х0,51 7.3 38.87 104
10308813 3х2х0,51 7.7 44.46 120
10308814 4х2х0,51 8.0 51.30 137
10308815 5х2х0,51 9.0 58.49 159
10308816 6х2х0,51 10.3 65.79 178
10308817 8х2х0,51 13.8 76.97 209
10308818 10х2х0,51 16.6 92.71 255
10308819 14х2х0,51 18.1 105.14 287
10308820 20х2х0,51 24.1 146.31 386
10308821 1х2х0,8 5.7 31.54 76
10308822 2х2х0,8 9.3 54.78 134
10308823 3х2х0,8 9.8 66.38 159
10308824 4х2х0,8 10.1 79.48 185
10308825 5х2х0,8 11.4 92.99 217
10308826 6х2х0,8 13.2 106.64 245
10308827 8х2х0,8 17.7 129.83 288
10308828 10х2х0,8 21.6 158.50 355
10308829 14х2х0,8 23.5 183.20 403
10308830 20х2х0,8 31.7 271.71 565
10308831 1х2х1,05 6.3 40.94 92
10308832 2х2х1,05 10.5 73.58 167
10308833 3х2х1,05 10.9 92.44 198
10308834 4х2х1,05 11.4 113.09 239
10308835 5х2х1,05 13.1 134.22 286
10308836 6х2х1,05 15.1 155.52 325
10308837 8х2х1,05 20.6 193.24 394
10308838 10х2х1,05 24.5 237.45 480
10308839 14х2х1,05 27.4 276.97 556
10308840 20х2х1,05 36.9 422.86 797
10308841 1х2х1,38 7.5 55.50 118
10308842 2х2х1,38 12.7 102.70 217
10308843 3х2х1,38 13.6 133.91 268
10308844 4х2х1,38 13.7 167.19 321
10308845 5х2х1,38 16.6 201.03 386
10308846 6х2х1,38 18.3 235.06 448
10308847 8х2х1,38 24.9 297.48 543
10308848 10х2х1,38 30.4 367.42 670
10308849 14х2х1,38 33.2 431.90 773
10308850 20х2х1,38 45.0 675.74 1132

similar products