catalog

КОНелНнг-HF (J-НCHU-PF) Communication and alarm cable, shielded, twisted pair, halogen-free

КОНелНнг-HF (J-НCHU-PF)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • Alarm systems, access control systems, management, control, communication and telecommunication systems
  • For the transmission of low-power electrical signals
  • For installation of station equipment, for stationary installation inside buildings, structures, in dry and wet areas

ADVANTAGES

  • Shields protect against electromagnetic waves and absorb external electromagnetic signals
  • The wires have been tested for use outside the hermetic zone in cable structures of NPP premises, in systems of classes 3, 4 according to NP 306.2.141-2008
  • Additional versions: armoring, hydrophobicity, oil resistance

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

halogen-free composition

Outer shell

halogen-free red composition

Number of cores

1÷61х2

Screen

Synthetic film foiled with aluminum + grounding conductor

Screen 1

braid of copper ("el" - tinned) wires

Screen 2

shielded pairs

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

0,4
160

0,51
110

0,8
36

1,05
24,5

1,13
18,1

1,38
12,1

1,78
7,41

Temperature range

-30˚С to +70˚С

Test voltage

1500 W

Operating voltage

300 W

Electrical resistance of insulation

100 megohms/km

Minimum bending radius

10 х D

Color identification of cores

DSTU IEC 60189-2

Electrical capacity

100 pF/m

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosive activity - clause 4.6 of DSTU 4809. p.4.6 DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10305101 1х2х0,4 4.4 20.52 54
10305102 2х2х0,4 6.9 32.74 92
10305103 3х2х0,4 7.2 36.6 104
10305104 4х2х0,4 7.4 41.55 118
10305105 5х2х0,4 8.5 46.78 139
10305106 6х2х0,4 9.6 52.12 154
10305107 8х2х0,4 12.7 59.84 176
10305108 10х2х0,4 15.3 71.50 214
10305109 14х2х0,4 16.6 80.30 239
10305110 20х2х0,4 22.1 108.13 315
10305111 1х2х0,51 4.6 23.59 60
10305112 2х2х0,51 7.3 38.87 106
10305113 3х2х0,51 7.7 44.46 123
10305114 4х2х0,51 8.0 51.3 140
10305115 5х2х0,51 9.0 58.49 162
10305116 6х2х0,51 10.3 65.79 182
10305117 8х2х0,51 13.8 76.97 213
10305118 10х2х0,51 16.6 92.71 261
10305119 14х2х0,51 18.1 105.14 293
10305120 20х2х0,51 24.1 146.31 395
10305121 1х2х0,8 5.7 31.54 77
10305122 2х2х0,8 9.3 54.78 137
10305123 3х2х0,8 9.8 66.38 162
10305124 4х2х0,8 10.1 79.48 189
10305125 5х2х0,8 11.4 92.99 221
10305126 6х2х0,8 13.2 106.64 250
10305127 8х2х0,8 17.7 129.83 294
10305128 10х2х0,8 21.6 158.5 362
10305129 14х2х0,8 23.5 183.2 441
10305130 20х2х0,8 31.7 271.71 576
10305131 1х2х1,05 6.3 40.94 93
10305132 2х2х1,05 10.5 73.58 170
10305133 3х2х1,05 10.9 92.44 202
10305134 4х2х1,05 11.4 113.09 243
10305135 5х2х1,05 13.1 134.22 291
10305136 6х2х1,05 15.1 155.52 331
10305137 8х2х1,05 20.6 193.24 401
10305138 10х2х1,05 24.5 237.45 488
10305139 14х2х1,05 27.4 276.97 566
10305140 20х2х1,05 36.9 422.86 810
10305141 1х2х1,38 7.5 55.5 120
10305142 2х2х1,38 12.7 102.7 221
10305143 3х2х1,38 13.6 133.91 272
10305144 4х2х1,38 13.7 167.19 327
10305145 5х2х1,38 16.6 201.03 393
10305146 6х2х1,38 18.3 235.06 456
10305147 8х2х1,38 24.9 297.48 552
10305148 10х2х1,38 30.4 367.42 681
10305149 14х2х1,38 33.2 431.9 785
10305150 20х2х1,38 45.0 675.74 1149

similar products