catalog

КОПелНнг-HF (J-2YСH-PF) Communication and alarm cable with improved communication characteristics, shielded, twisted pair, halogen-free

КОПелНнг-HF (J-2YСH-PF)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • Alarm systems, access control systems, management, control, communication and telecommunication systems
  • For the transmission of low-power electrical signals
  • For installation of station equipment, for stationary installation inside buildings, structures, in dry and wet areas

ADVANTAGES

  • Shields protect against electromagnetic waves and absorb external electromagnetic signals
  • The wires have been tested for use outside the hermetic zone in cable structures of NPP premises, in systems of classes 3, 4 according to NP 306.2.141-2008
  • Additional versions: armoring, hydrophobicity, oil resistance

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

Polyethylene

Outer shell

White polyvinyl chloride plastic.

Number of cores

1÷61х2

Screen

tinned wire braid

Screen 1

braid of copper ("el" - tinned) wires

Screen 2

shielded pairs

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

0,4
160

0,51
110

0,8
36

1,05
24,5

1,13
18,1

1,38
12,1

1,78
7,41

Temperature range

-30˚С to +70˚С

Test voltage

2500 W

Operating voltage

72 W

Electrical resistance of insulation

500 MOhm/km

Minimum bending radius

8 х D

Color identification of cores

DSTU IEC 60189-2

Electrical capacity

56 pF/m

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Burning in bundles - p.4.2 of DSTU 4809, DSTU EN 60332-3-22.

Toxicity - p. 4.3 DSTU 4809

Smoke smoke - clause 4.4 of DSTU 4809

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2

Halogens and corrosive activity - clause 4.6 of DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10301501 1х2х0,4 4.4 20.52 52
10301502 2х2х0,4 6.9 32.74 89
10301503 3х2х0,4 7.2 36.6 100
10301504 4х2х0,4 7.4 41.55 113
10301505 5х2х0,4 8.5 46.78 132
10301506 6х2х0,4 9.6 52.12 146
10301507 8х2х0,4 12.7 59.84 165
10301508 10х2х0,4 15.3 71.5 200
10301509 14х2х0,4 16.6 80.3 223
10301510 20х2х0,4 22.1 108.13 288
10301511 1х2х0,51 4.6 23.59 58
10301512 2х2х0,51 7.3 38.87 102
10301513 3х2х0,51 7.7 44.46 117
10301514 4х2х0,51 8.0 51.3 133
10301515 5х2х0,51 9.0 58.49 153
10301516 6х2х0,51 10.3 65.79 171
10301517 8х2х0,51 13.8 76.97 199
10301518 10х2х0,51 16.6 92.71 243
10301519 14х2х0,51 18.1 105.14 272
10301520 20х2х0,51 24.1 146.31 359
10301521 1х2х0,8 5.7 31.54 75
10301522 2х2х0,8 9.3 54.78 132
10301523 3х2х0,8 9.8 66.38 155
10301524 4х2х0,8 10.1 79.48 180
10301525 5х2х0,8 11.4 92.99 209
10301526 6х2х0,8 13.2 106.64 236
10301527 8х2х0,8 17.7 129.83 275
10301528 10х2х0,8 21.6 158.5 338
10301529 14х2х0,8 23.5 183.2 383
10301530 20х2х0,8 31.7 271.71 529
10301531 1х2х1,05 6.3 40.94 90
10301532 2х2х1,05 10.5 73.58 164
10301533 3х2х1,05 10.9 92.44 193
10301534 4х2х1,05 11.4 113.09 231
10301535 5х2х1,05 13.1 134.22 276
10301536 6х2х1,05 15.1 155.52 313
10301537 8х2х1,05 20.6 193.24 377
10301538 10х2х1,05 24.5 237.45 458
10301539 14х2х1,05 27.4 276.97 530
10301540 20х2х1,05 36.9 422.86 749
10301541 1х2х1,38 7.5 55.5 116
10301542 2х2х1,38 12.7 102.7 214
10301543 3х2х1,38 13.6 133.91 261
10301544 4х2х1,38 13.7 167.19 312
10301545 5х2х1,38 16.6 201.03 374
10301546 6х2х1,38 18.3 235.06 434
10301547 8х2х1,38 24.9 297.48 522
10301548 10х2х1,38 30.4 367.42 644
10301549 14х2х1,38 33.2 431.9 741
10301550 20х2х1,38 45.0 675.74 1075