КМНЕ1ЕНнг-HF (JE-LiH(St)HU-PIMF) 5th class of flexibility Control and data transmission cables, shielded
Stability during single burning
Stability when burning in a bundle
Halogen-free
FIELD OF APPLICATION
- Construction, energy, industrial and transportation facilities
- Data transmission in signaling, instrumentation and control systems, automated control systems, monitoring and special applications
- In rooms with dry or humid environments under normal mechanical loads
ADVANTAGES
- Flexible
- The cables are tested for laying outside the hermetic zone in cable structures and premises of NPPs, in systems of classes 3, 4 according to NP 306.2.141-2008
- The presence of a shield protects against electromagnetic waves
- Additional versions: oil-resistant, armored
CONSTRUCTION
|
Resin |
Copper ("l" - tinned) stranded conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 5 |
|
Insulation |
halogen-free composition |
|
Outer shell |
halogen-free red composition |
|
Number of cores |
1÷61х2 |
|
Screen 1 |
Synthetic film foiled with aluminum + grounding conductor |
|
Screen 2 |
Aluminum foiled synthetic film |
TECHNICAL CHARACTERISTICS
Electrical resistance depending on the rated area cross-section of the conductor, not more:
mm²
Ohm/km
0,2
110
0,28
67
0,5
39
0,75
26
1,0
19,5
1,5
13,3
2,5
7,98
|
Temperature range |
-40˚C to +70˚C |
|
Test voltage |
2000 V (2.5 mm2 - 2500 V) |
|
Operating voltage |
300/500 W |
|
Electrical resistance of insulation |
10 MOhm/km |
|
Minimum bending radius |
7,5 х D |
|
Color identification of cores |
DSTU IEC 60189-2, DIN 47100 |
|
Electrical capacity |
120 pF/m |
COMPLIANCE / STANDARDS
Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2
Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22
Toxicity - p. 4.3 DSTU 4809.
Smoke smoke - clause 4.4 of DSTU 4809.
Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2
Halogens and corrosive activity - clause 4.6 of DSTU 4809, DSTU EN 60754-2
TABLE OF NOMENCLATURES
| Article no. | Number of cores and cross section mm2 |
Maximum outer diameter |
Mass of copper | Mass. |
|---|---|---|---|---|
| 10535001 | 1х2х0,2 | 5.0 | 32.480 | 85 |
| 10535002 | 2х2х0,2 | 8.0 | 52.594 | 134 |
| 10535004 | 4х2х0,2 | 8.7 | 78.746 | 188 |
| 10535005 | 5х2х0,2 | 9.8 | 92.862 | 218 |
| 10535016 | 1х2х0,5 | 7.2 | 42.757 | 115 |
| 10535017 | 2х2х0,5 | 11.8 | 71.145 | 186 |
| 10535019 | 4х2х0,5 | 12.7 | 108.586 | 276 |
| 10535020 | 5х2х0,5 | 14.3 | 128.735 | 323 |
| 10535023 | 1х2х0,75 | 7.4 | 49.451 | 131 |
| 10535024 | 2х2х0,75 | 13.3 | 83.818 | 215 |
| 10535026 | 4х2х0,75 | 14.4 | 131.345 | 319 |
| 10535027 | 5х2х0,75 | 16.3 | 156.674 | 386 |
| 10535037 | 1х2х1,5 | 9.5 | 61.512 | 156 |
| 10535038 | 2х2х1,5 | 16.2 | 106.749 | 260 |
| 10535040 | 4х2х1,5 | 17.8 | 172.898 | 406 |
| 10535041 | 5х2х1,5 | 20.4 | 207.769 | 492 |
| 10535044 | 1х2х2,5 | 11.1 | 85.264 | 203 |
| 10535045 | 2х2х2,5 | 19.4 | 152.324 | 353 |
| 10535047 | 4х2х2,5 | 21.8 | 257.063 | 587 |
| 10535048 | 5х2х2,5 | 24.6 | 311.603 | 696 |