catalog

КМНЕ1ЕНнг-HF (JE-LiH(St)HU-PIMF) 2 class of flexibility Control and data transmission cables, shielded

КМНЕ1ЕНнг-HF (JE-LiH(St)HU-PIMF) 2 class of flexibility
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

FIELD OF APPLICATION

  • Construction, energy, industrial and transportation facilities
  • Data transmission in signaling, instrumentation and control systems, automated control systems, monitoring and special applications
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • Flexible
  • The cables are tested for laying outside the hermetic zone in cable structures and premises of NPPs, in systems of classes 3, 4 according to NP 306.2.141-2008
  • The presence of a shield protects against electromagnetic waves
  • Additional versions: oil-resistant, armored

CONSTRUCTION

Resin

Copper ("l" - tinned) stranded conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 2

Insulation

halogen-free composition

Outer shell

halogen-free red composition

Number of cores

1÷61х2

Screen 1

Synthetic film foiled with aluminum + grounding conductor

Screen 2

Aluminum foiled synthetic film

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,2
110

0,28
67

0,5
36

0,75
24,5

1,0
18,1

1,5
12,1

2,5
7,41

Temperature range

-40˚C to +70˚C

Test voltage

2000 V (2.5 mm2 - 2500 V)

Operating voltage

300/500 W

Electrical resistance of insulation

10 MOhm/km

Minimum bending radius

7,5 х D

Color identification of cores

DSTU IEC 60189-2, DIN 47100

Electrical capacity

120 pF/m

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2

Halogens and corrosive activity - clause 4.6 of DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10435001 1х2х0,2 5.0 32.480 85
10435002 2х2х0,2 8.0 52.594 134
10435004 4х2х0,2 8.7 78.746 188
10435005 5х2х0,2 9.8 92.862 218
10435016 1х2х0,5 7.2 42.757 115
10435017 2х2х0,5 11.8 71.145 186
10435019 4х2х0,5 12.7 108.586 276
10435020 5х2х0,5 14.3 128.735 323
10435023 1х2х0,75 7.4 49.451 131
10435024 2х2х0,75 13.3 83.818 215
10435026 4х2х0,75 14.4 131.345 319
10435027 5х2х0,75 16.3 156.674 386
10435037 1х2х1,5 9.5 61.512 156
10435038 2х2х1,5 16.2 106.749 260
10435040 4х2х1,5 17.8 172.898 406
10435041 5х2х1,5 20.4 207.769 492
10435044 1х2х2,5 11.1 85.264 203
10435045 2х2х2,5 19.4 152.324 353
10435047 4х2х2,5 21.8 257.063 587
10435048 5х2х2,5 24.6 311.603 696

similar products