КМлПЕелВ (JE-Li2Y(St)CY-PF) 2 class of flexibility Symmetrical interface cable BUS
Stability during single burning
FIELD OF APPLICATION
- They are used in networks operating according to such standards as RS-232, RS-422, RS-485, Profibus, CAN, LON, and others
ADVANTAGES
- High data transfer rate
- The cables are tested for laying outside the hermetic zone in cable structures and premises of NPPs, in systems of classes 3, 4 according to NP 306.2.141-2008
- Additional versions: armored
CONSTRUCTION
|
Resin |
Copper tinned stranded conductors in accordance with the requirements of DSTU EN 60228, flexibility class 2 |
|
Insulation |
Polyethylene |
|
Outer shell |
Polyvinyl chloride plastic of purple color. |
|
Number of cores |
1÷4х2 |
|
Screen 1 |
Synthetic film foiled with aluminum + grounding conductor (drainage core) made of tinned copper wires |
|
Screen 2 |
Braid made of tinned copper wires |
TECHNICAL CHARACTERISTICS
Electrical resistance depending on the rated area cross-section of the conductor, not more:
mm²
Ohm/km
0,6
100
0,78
59
|
Temperature range |
-40˚C to +70˚C |
|
Test voltage |
2000 В |
|
Operating voltage |
300 W |
|
Electrical resistance of insulation |
500 MOhm/km |
|
Minimum bending radius |
7,5 х D |
|
Color identification of cores |
DSTU IEC 60189-2 |
|
Electrical capacity |
40±4 pF/m |
|
Wave resistance |
1 kHz 120±14 ohms |
COMPLIANCE / STANDARDS
ISO/IEC 8482
Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2
TABLE OF NOMENCLATURES
| Article no. | Number of cores and cross section mm2 |
Maximum outer diameter |
Mass of copper | Mass. |
|---|---|---|---|---|
| 10412351 | 1х2х0,6 | 9,1 | 4,02 | 74 |
| 10412352 | 2х2х0,6 | 13,6 | 8,04 | 123 |
| 10412354 | 1х2х0,78 | 9,8 | 6,79 | 82 |
| 10412355 | 2х2х0,78 | 14,7 | 13,59 | 138 |
| 10412353 | 4х2х0,6 | 15,8 | 62 | 173 |
| 10412356 | 4х2х0,78 | 17,1 | 78 | 194 |