ALAY-net F/UTP LSOH CAT.5E Network cable, shielded, twisted pair, with low smoke and gas emission
Stability during single burning
Stability when burning in a bundle
Resistant to electrical influences-shielded
FIELD OF APPLICATION
- For construction of structured cable systems
- Data transfer at speeds up to 100 Mbps
- ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T (up to 55 meters)
ADVANTAGES
- The cables are tested for laying outside the hermetic zone in cable structures and premises of NPPs, in systems of classes 3, 4 according to the classification of NP 306.2.141-2008
- Meet the requirements of the RoHS Directive
- Version: for outdoor use, with cable
- Screens protect against interference
CONSTRUCTION
|
Resin |
Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1 |
|
Insulation |
Polyethylene |
|
Outer shell |
White polyvinyl chloride plastic. |
|
Number of cores |
2х2, 4х2 |
|
Screen |
Synthetic film foiled with aluminum + grounding conductor |
TECHNICAL CHARACTERISTICS
Electrical resistance depending on the nominal diameter of the core, not more than:
mm
Ohm/km
0,51 (24 AWG)
96
|
Temperature range |
-30˚С to +70˚С |
||||||||||||||||||||||||||||||||||||
|
Test voltage |
2500 W |
||||||||||||||||||||||||||||||||||||
|
Operating voltage |
72 W |
||||||||||||||||||||||||||||||||||||
|
Electrical resistance of insulation |
5 Gohm/km |
||||||||||||||||||||||||||||||||||||
|
Minimum bending radius |
10 х D |
||||||||||||||||||||||||||||||||||||
|
Color identification of cores |
DSTU IEC 61156-1 |
||||||||||||||||||||||||||||||||||||
|
Signal transmission characteristics
|
|||||||||||||||||||||||||||||||||||||
|
Electrical capacity |
56 pF/m |
||||||||||||||||||||||||||||||||||||
|
Wave impedance in the frequency range of 1-100 MHz |
100±10 Ом |
||||||||||||||||||||||||||||||||||||
COMPLIANCE / STANDARDS
DSTU ISO/IEC 11801
DSTU IEC 61156-5
Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2
TABLE OF NOMENCLATURES
| Article no. | Number of cores and cross section mm2 |
Maximum outer diameter |
Mass of copper | Mass. |
|---|---|---|---|---|
| 10200401 | 2х2х0,51 | 5.8 | 8.74 | 36 |
| 10200402 | 4х2х0,51 | 6.6 | 16.37 | 50 |
