catalog

КМРкЕеН FRHF FE180/Eк30 (JE-LiHX(St)СH-PF FE180) парної скрутки 6-класс гнучкості Control and data cable, shielded, flexible, twisted pair, flame retardant

КМРкЕеН FRHF FE180/Eк30 (JE-LiHX(St)СH-PF FE180) парної скрутки 6-класс гнучкості
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • Construction, energy, industry, transportation, evacuation, fire extinguishing, smoke removal, emergency power supply and fire warning systems
  • For stationary installation in automatic control and monitoring systems of power circuits
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • Flexible
  • Preservation of circuit integrity, under standard temperature conditions, for 30 minutes at temperatures from ~842˚C (Eq30)
  • It does not emit corrosive gaseous products in case of fire. gaseous products, which prevents possible damage to electronic equipment
  • Pair twisting of the cores reduces crosstalk and mutual interference
  • The shields protect the cable from external influences, electrical and magnetostatic effects
  • The cables are tested for installation outside the hermetic zone in cable structures and NPP premises in systems of classes: 2, 3, 4 according to the classification of NP 306.2.141-2008
  • Additional versions: armored

CONSTRUCTION

Resin

Copper ("l" - tinned) stranded conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 2, 5 or 6

Insulation

Organosilicon rubber

Outer shell

Orange halogen-free polymer composition

Number of cores

1÷61х2

Screen 1

synthetic film foiled with aluminum + grounding conductor

Screen 2

Braid of copper ("el" - tinned) wires

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,5
39

0,75
26

1,0
26

1,5
13,3

2,5
7,98

Temperature range

-40˚C to +70˚C

Test voltage

2000 V (2.5 mm2 - 2500 V)

Operating voltage

300/500 W

Electrical resistance of insulation

200 MOhm/km

Minimum bending radius

7,5 х D

Color identification of cores

DSTU IEC 60189-2, DIN 47100

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.

Standard temperature conditions (clause 4.7 of DSTU 4809).

Integrity of circuits under conditions of exposure to flame with a temperature of at least 750˚C - 4.8 DSTU 4809, DSTU IEC 60331-21

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10637301 1х2х0,2 11.58 37.31 142
10637302 2х2х0,2 15.25 60.52 218
10637304 4х2х0,2 17.18 88.29 298
10637305 5х2х0,2 18.78 104.35 352
10637316 1х2х0,5 12.17 44.07 156
10637317 2х2х0,5 16.23 73.31 245
10637319 4х2х0,5 18.60 111.98 350
10637320 5х2х0,5 20.10 132.44 405
10637323 1х2х0,75 12.68 50.52 171
10637324 2х2х0,75 17.06 85.58 271
10637326 4х2х0,75 19.60 134.25 394
10637327 5х2х0,75 21.69 159.84 476
10637337 1х2х1,5 13.56 62.30 196
10637338 2х2х1,5 18.74 108.84 327
10637340 4х2х1,5 21.33 175.25 472
10637341 5х2х1,5 23.63 210.31 572
10637344 1х2х2,5 15.03 85.76 242
10637345 2х2х2,5 21.61 153.92 432
10637347 4х2х2,5 24.93 259.62 651
10637348 5х2х2,5 27.58 314.27 789