КМРкeН FRHF FE180/Eк30 (JE-LiHXCH-PF FE180) twisted pair cable, 2nd flexibility class Control and data cable, shielded, flexible, twisted pair, flame retardant
Stability during single burning
Stability when burning in a bundle
Halogen-free
Resistant to electrical influences-shielded
FIELD OF APPLICATION
- Construction, energy, industry, transportation, evacuation, fire extinguishing, smoke removal, emergency power supply and fire warning systems
- For stationary installation in automatic control and monitoring systems of power circuits
- In rooms with dry or humid environments under normal mechanical loads
ADVANTAGES
- Flexible
- Preservation of circuit integrity, under standard temperature conditions, from 30 to 90 minutes at temperatures from ~842˚C (Ek30) to ~1006˚C (Ek90)
- It does not emit corrosive gaseous products in case of fire. gaseous products, which prevents possible damage to electronic equipment
- Pair twisting of the cores reduces crosstalk and mutual interference
- The presence of an "E" shield protects the information signal from electromagnetic fields. from electromagnetic fields, high quality of information transmission is maintained
- The cables are tested for installation outside the hermetic zone in cable structures and NPP premises in systems of classes: 2, 3, 4 according to the classification of NP 306.2.141-2008
- Additional versions: armored
CONSTRUCTION
|
Resin |
Copper ("l" - tinned) stranded conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 2, 5 or 6 |
|
Insulation |
Organosilicon rubber |
|
Outer shell |
Orange halogen-free polymer composition |
|
Number of cores |
1÷61х2 |
|
Screen |
Braid of copper ("el" - tinned) wires |
|
Screen 1 |
synthetic film foiled with aluminum + grounding conductor |
TECHNICAL CHARACTERISTICS
Electrical resistance depending on the rated area cross-section of the conductor, not more:
mm²
Ohm/km
0,2
110
0,28
67
0,5
36
0,75
24,5
1,0
18,1
1,5
12,1
2,5
7,41
|
Temperature range |
-40˚C to +80˚C |
|
Test voltage |
2000 V (2.5 mm2 - 2500 V) |
|
Operating voltage |
300/500 W |
|
Electrical resistance of insulation |
200 MOhm/km |
|
Minimum bending radius |
7,5 х D |
|
Color identification of cores |
DIN 47100, EN 50334 |
COMPLIANCE / STANDARDS
Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2
Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22
Toxicity - p. 4.3 DSTU 4809.
Smoke smoke - clause 4.4 of DSTU 4809.
Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.
Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.
Standard temperature conditions (clause 4.7 of DSTU 4809).
Integrity of circuits under conditions of exposure to flame with a temperature of at least 750˚C - 4.8 DSTU 4809, DSTU IEC 60331-21
TABLE OF NOMENCLATURES
| Article no. | Number of cores and cross section mm2 |
Maximum outer diameter |
Mass of copper | Mass. |
|---|---|---|---|---|
| 10437101 | 1х2х0,2 | 5.0 | 8.11 | 23 |
| 10437102 | 2х2х0,2 | 8.0 | 15.11 | 47 |
| 10437104 | 4х2х0,2 | 8.7 | 29.10 | 75 |
| 10437105 | 5х2х0,2 | 9.8 | 36.09 | 91 |
| 10437116 | 1х2х0,5 | 7.2 | 18.25 | 50 |
| 10437117 | 2х2х0,5 | 11.8 | 35.39 | 96 |
| 10437119 | 4х2х0,5 | 12.7 | 69.67 | 154 |
| 10437120 | 5х2х0,5 | 14.3 | 86.80 | 185 |
| 10437123 | 1х2х0,75 | 7.4 | 25.27 | 63 |
| 10437124 | 2х2х0,75 | 13.3 | 49.43 | 121 |
| 10437126 | 4х2х0,75 | 14.4 | 97.74 | 204 |
| 10437127 | 5х2х0,75 | 16.3 | 121.90 | 245 |
| 10437137 | 1х2х1,5 | 9.5 | 43.73 | 94 |
| 10437138 | 2х2х1,5 | 16.2 | 86.34 | 182 |
| 10437140 | 4х2х1,5 | 17.8 | 171.57 | 320 |
| 10437141 | 5х2х1,5 | 20.4 | 214.18 | 399 |
| 10437144 | 1х2х2,5 | 11.1 | 67.67 | 131 |
| 10437145 | 2х2х2,5 | 19.4 | 134.22 | 263 |
| 10437147 | 4х2х2,5 | 21.8 | 267.32 | 490 |
| 10437148 | 5х2х2,5 | 24.6 | 333.88 | 592 |