catalog

КМРкHс FRHF FE180/Eк90 0,6/1 кВ (LIНХН-FE180) Power cable, flexible, fire-resistant

КМРкHс FRHF FE180/Eк90 0,6/1 кВ (LIНХН-FE180)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

FIELD OF APPLICATION

  • Construction, energy, industry, transportation facilities in evacuation, fire extinguishing, smoke removal, emergency power supply and fire warning systems
  • For fixed installation in power and lighting networks
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • Preservation of circuit integrity, under standard temperature conditions, from 30 to 90 minutes at temperatures from ~842˚C (Ek30) to ~1006˚C (Ek90)
  • Does not emit corrosive gaseous products in fire conditions gaseous products
  • The cables are used for laying outside the hermetic zone in cable structures and NPP premises in systems of classes 2, 3, 4 according to NP 306.2.141-2008

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1 or 2

Insulation

Organosilicon rubber

Outer shell

Halogen-free composition in orange color

Number of cores

2, 3, 4, 5

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,5
36

1,0
18,1

1,5
12,1

2,5
7,41

4
4,61

6
3,08

10
1,83

16
1,15

25
0,727

35
0,524

Temperature range

-40˚C to +80˚C

Test voltage

4000 W

Operating voltage

600/1000 W

Electrical resistance of insulation

100 megohms/km

Minimum bending radius

12 х D

Color identification of cores

DSTU HD 308 S2

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.

Standard temperature conditions (clause 4.7 of DSTU 4809).

Integrity of circuits under conditions of exposure to flame with a temperature of at least 750 ° C - clause 4.6 of which is at least 750 ° C - 4.8 DSTU 4809, DSTU IEC 60331-21

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
11304501 2х0,5 6.6 9.21 38
11304502 3х0,5 6.9 13.82 48
11304503 4х0,5 7.7 18.43 62
11304504 5х0,5 8.3 23.03 74
11304505 2х0,75 7.2 13.82 49
11304506 3х0,75 7.4 20.73 64
11304507 4х0,75 8.3 27.64 81
11304508 5х0,75 9.1 34.55 97
11304509 2х1,0 8.1 18.43 59
11304510 3х1,0 8.6 27.64 77
11304511 4х1,0 9.6 36.85 102
11304512 5х1,0 10.4 46.06 122
11304513 2х1,5 8.7 27.64 74
11304514 3х1,5 9.2 41.46 98
11304515 4х1,5 10.4 55.28 133
11304516 5х1,5 11.4 69.10 162
11304517 2х2,5 10.1 46.06 101
11304518 3х2,5 11.0 69.10 142
11304519 4х2,5 12.2 92.13 186
11304520 5х2,5 13.4 115.16 225
11304521 2х4,0 12.2 73.70 152
11304522 3х4,0 13.2 110.55 204
11304523 4х4,0 14.6 147.41 260
11304524 5х4,0 16.6 184.26 333
11304525 2х6,0 13.9 110.55 199
11304526 3х6,0 14.7 165.83 273
11304527 4х6,0 16.8 221.11 367
11304528 5х6,0 18.5 276.39 446
11304529 2х10 16.8 184.26 311
11304530 3х10 18.9 276.39 429
11304531 4х10 20.3 368.51 551
11304532 5х10 23.3 460.64 691
11304533 2х16 19.6 294.81 444
11304534 3х16 21.3 442.22 623
11304535 4х16 24.5 589.62 824
11304536 5х16 27.2 737.03 1010
11304537 2х25 24.0 460.64 673
11304538 3х25 26.4 690.96 948
11304539 4х25 29.4 921.28 1231
11304540 5х25 33.2 1151.60 1523
11304541 2х35 27.5 644.90 886
11304542 3х35 29.5 967.35 1261
11304543 4х35 33.3 1289.80 1643
11304544 5х35 37.1 1612.25 2037