catalog

КОРкНс FRНF FE180/Eк90 (НХН-FE180) Power cable, fire resistant

КОРкНс FRНF FE180/Eк90 (НХН-FE180)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

FIELD OF APPLICATION

  • Construction, energy, industry, transportation facilities in evacuation, fire extinguishing, smoke removal, emergency power supply and fire warning systems
  • For fixed installation in power and lighting networks
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • Preservation of circuit integrity, under standard temperature conditions, from 30 to 90 minutes at temperatures from ~842˚C (Ek30) to ~1006˚C (Ek90)
  • Does not emit corrosive gaseous products in fire conditions gaseous products
  • The cables are used for laying outside the hermetic zone in cable structures and NPP premises in systems of classes 2, 3, 4 according to NP 306.2.141-2008

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1 or 2

Insulation

Organosilicon rubber

Outer shell

Halogen-free composition in orange color

Number of cores

2, 3, 4, 5

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

0,5
36

1,0
18,1

1,5
12,1

2,5
7,41

4
4,61

6
3,08

10
1,83

Temperature range

-40˚C to +80˚C

Test voltage

2500 W

Operating voltage

300/500 W

Electrical resistance of insulation

100 megohms/km

Minimum bending radius

15 х D

Color identification of cores

DSTU HD 308 S2

Electrical capacity

100 pF/m

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.

Standard temperature conditions (clause 4.7 of DSTU 4809).

Integrity of circuits under conditions of exposure to flame with a temperature of at least 750 ° C - clause 4.6 of which is at least 750 ° C - 4.8 DSTU 4809, DSTU IEC 60331-21

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
11303401 2х0,5 6.0 9.21 38
11303402 3х0,5 6.4 13.82 48
11303403 4х0,5 7.0 18.43 62
11303404 5х0,5 7.8 23.03 74
11303405 2х0,75 6.8 13.82 49
11303406 3х0,75 7.2 20.73 64
11303407 4х0,75 8.0 27.64 81
11303408 5х0,75 8.8 34.55 97
11303409 2х1,0 7.4 18.43 59
11303410 3х1,0 7.8 27.64 77
11303411 4х1,0 9.0 36.85 102
11303412 5х1,0 9.9 46.06 122
11303413 2х1,5 8.2 27.64 74
11303414 3х1,5 8.7 41.46 98
11303415 4х1,5 10.0 55.28 133
11303416 5х1,5 10.9 69.10 162
11303417 2х2,5 9.6 46.06 101
11303418 3х2,5 10.4 69.10 142
11303419 4х2,5 11.7 92.13 186
11303420 5х2,5 12.9 115.16 225
11303421 2х4,0 11.6 73.70 152
11303422 3х4,0 13.2 110.55 204
11303423 4Х4,0 14.6 147.41 260
11303424 5х4,0 16.6 184.26 333
11303425 2х6,0 13.1 110.55 199
11303426 3х6,0 14.6 165.83 273
11303427 4х6,0 16.8 221.11 367
11303428 5х6,0 18.5 276.39 446