catalog

UNIMATIC® BUS PA Symmetrical interface cable for BUS systems, shielded

UNIMATIC® BUS PA
icon_red_1

Stability during single burning

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • PA-BUS component connections are used in networks operating according to such standards as RS-232, RS-422, RS-485, Profibus, CAN, LON, etc.
  • For connecting sensors and actuators in hazardous areas

ADVANTAGES

  • High data transfer rate
  • High degree of protection against electromagnetic fields

CONSTRUCTION

Resin

Copper conductors in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

Polyethylene foam

Outer shell

Polyvinyl chloride plastic of gray or purple color

Number of cores

2

Screen 1

Synthetic aluminum foil tape

Screen 2

Braid made of tinned copper wires

Filling in

Polyvinyl chloride plastic

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

1 (18/1 AWG)
18,1

Temperature range:
-in fixed installation
-conditions during installation

from -40˚С to +70˚С
from -5°C to +70°C

Test voltage

1500 W

Operating voltage

300/500 W

Electrical resistance of insulation

1 Gohm/km

Minimum bending radius

7,5 х D

Color identification of cores

red, green

Electrical capacity

55 pF/m

Wave resistance

100±20 ohms

COMPLIANCE / STANDARDS

Resistance to single combustion, DSTU EN 60332-1-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
30400501 1х2х1 9,6 25,9 103