catalog

PSVEVng-LS (J-Y(St)Y-LS) Communication and alarm wires, shielded, with low smoke emission

PSVEVng-LS (J-Y(St)Y-LS)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • Alarm systems, access control systems, management, control, communication and telecommunication systems
  • For the transmission of low-power electrical signals
  • For installation of station equipment, for stationary installation inside buildings, structures, in dry and wet areas

ADVANTAGES

  • The presence of the “E” shield protects the information signal from electromagnetic fields. High quality of information transmission is maintained from electromagnetic fields
  • The wires have been tested for use outside the hermetic zone in cable structures of NPP premises, in systems of classes 3, 4 according to NP 306.2.141-2008
  • Low cost, simple design and reliability in long-term operation
  • Additional versions: armored, hydrophobic, oil resistant

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

polyvinyl chloride plastic of reduced fire hazard

Outer shell

low smoke emission polyvinyl chloride plastic in red or black color

Number of cores

2, 4, 6, 8, 10, 12÷61

Screen

Synthetic film foiled with aluminum + grounding conductor

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

0,4
160

0,5
110

0,8
36

1,05
24,5

1,13
18,1

1,38
12,1

1,78
7,41

Temperature range

-50˚С to +70˚С

Test voltage

1000 W

Operating voltage

300 W

Electrical resistance of insulation

100 megohms/km

Minimum bending radius

10 х D

Color identification of cores

DSTU IEC 60304

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Toxicity - p. 4.3 of DSTU 4809

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2

Halogens and corrosive activity - clause 4.6 of DSTU 4809, DSTU EN 60754-2

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10101201 2х0,4 4.3 3.42 17
10101202 4х0,4 5.4 5.72 26
10101203 6х0,4 5.7 8.03 34
10101204 8х0,4 6.8 10.33 44
10101205 10х0,4 7.1 12.64 54
10101206 12х0,4 7.5 14.94 64
10101207 2х0,5 4.6 4.72 19
10101208 4х0,5 5.9 8.32 31
10101209 6х0,5 6.2 11.92 42
10101210 8х0,5 7.2 15.52 52
10101211 10х0,5 7.6 19.12 64
10101212 12х0,5 8 22.72 76
10101213 2х0,8 5.7 10.33 31
10101214 4х0,8 7 19.55 48
10101215 6х0,8 7.5 28.76 69
10101216 8х0,8 8.8 37.98 86
10101217 10х0,8 9.2 47.2 105
10101218 12х0,8 9.6 56.41 126
10101219 2х1,05 6.3 16.99 41
10101220 4х1,05 7.8 32.87 66
10101221 6х1,05 8.4 48.74 95
10101222 8х1,05 9.9 64.62 120
10101223 10х1,05 10.4 80.49 148
10101224 12х1,05 11 96.37 180
10101225 2х1,13 7.1 19.5 50
10101226 4х1,13 8.8 37.89 81
10101227 6х1,13 9.6 56.28 117
10101228 8х1,13 11.3 74.66 148
10101229 10х1,13 12 93.05 185
10101230 12х1,13 12.4 111.44 221
10101231 2х1,38 7.7 28.54 63
10101232 4х1,38 9.6 55.96 105
10101233 6х1,38 10.5 83.38 152
10101234 8х1,38 12.4 110.81 193
10101235 10х1,38 13.2 138.23 242
10101236 12х1,38 13.9 165.65 289
10101237 2х1,78 8.66 46.74 91
10101238 4х1,78 10.21 92.36 159
10101239 6х1,78 12.39 137.99 231
10101240 8х1,78 13.42 183.61 295
10101241 10х1,78 15.97 229.23 370
10101242 12х1,78 16.76 274.86 441