catalog

КОРкЕНк FRHF FE180/Eк30 (SL-НХ(St)Н FE180) Control cable, shielded, fireproof

КОРкЕНк FRHF FE180/Eк30 (SL-НХ(St)Н FE180)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • For stationary installation in automatic control and monitoring systems of power circuits
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • The cables are tested for installation outside the hermetic zone in cable structures and NPP premises in systems of classes: 2, 3, 4 according to the classification of NP 306.2.141-2008
  • Preservation of circuit integrity, under standard temperature conditions, from 30 to 90 minutes at temperatures from ~842˚C (Ek30) to ~1006˚C (Ek90)
  • The screen provides protection against electromagnetic waves

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

Organosilicon rubber

Outer shell

Orange halogen-free polymer composition

Number of cores

4, 5, 7, 10, 14, 19, 27, 37÷61

Screen

Synthetic film foiled with aluminum + grounding conductor.

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,5
36

1,0
18,1

1,5
12,1

2,5
7,41

Temperature range

-50˚С to +70˚С

Test voltage

2500 W

Operating voltage

300/500 W

Electrical resistance of insulation

20 MOhm/km

Minimum bending radius

15 х D

Color identification of cores

EN 50334

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.

Standard temperature conditions (clause 4.7 of DSTU 4809).

Integrity of circuits under conditions of exposure to flame with a temperature of at least 750 ° C - clause 4.6 of which is at least 750 ° C - 4.8 DSTU 4809, DSTU IEC 60331-21

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
11401101 2х0,5 7.6 10.33 49
11401102 3х0,5 8.0 14.94 60
11401103 4х0,5 8.7 19.54 72
11401104 5х0,5 10.0 24.15 97
11401105 7х0,5 10.8 33.36 120
11401106 10х0,5 13.4 47.18 162
11401107 14х0,5 14.4 65.61 205
11401108 19х0,5 15.9 88.64 259
11401109 27х0,5 18.9 125.49 348
11401110 37х0,5 21.5 171.55 470
11401111 2х0,75 8.3 14.94 59
11401112 3х0,75 8.7 21.85 73
11401113 4х0,75 10.0 28.76 102
11401114 5х0,75 10.8 35.67 120
11401115 7х0,75 11.7 49.48 150
11401116 10х0,75 14.6 70.21 205
11401117 14х0,75 15.8 97.85 261
11401118 19х0,75 17.5 132.40 333
11401119 27х0,75 21.3 187.68 471
11401120 37х0,75 23.7 256.77 612
11401121 2х1,0 8.8 19.54 69
11401122 3х1,0 9.9 28.76 100
11401123 4х1,0 10.7 37.97 121
11401124 5х1,0 11.6 47.18 143
11401125 7х1,0 12.6 65.61 180
11401126 10х1,0 15.7 93.25 247
11401127 14х1,0 17.0 130.10 319
11401128 19х1,0 18.9 176.16 409
11401129 27х1,0 23.0 249.86 579
11401130 37х1,0 25.7 341.99 756
11401131 2х1,5 10.0 28.76 97
11401132 3х1,5 10.6 42.57 122
11401133 4х1,5 11.5 56.39 149
11401134 5х1,5 12.5 70.21 177
11401135 7х1,5 13.5 97.85 227
11401136 10х1,5 17.0 139.31 313
11401137 14х1,5 18.5 194.59 409
11401138 19х1,5 21.0 263.68 548
11401139 27х1,5 25.0 374.24 750
11401140 37х1,5 28.4 512.43 1012
11401141 2х2,5 11.3 47.18 124
11401142 3х2,5 11.9 70.21 160
11401143 4х2,5 13.0 93.25 199
11401144 5х2,5 14.2 116.28 238
11401145 7х2,5 15.4 162.34 310
11401146 10х2,5 19.6 231.44 432
11401147 14х2,5 21.7 323.57 589
11401148 19х2,5 26.0 438.73 767
11401149 27х2,5 29.3 622.98 1083
11401150 37х2,5 32.8 853.30 1432
11401151 4х4,0 14.5 148.52 273
11401152 5х4,0 15.9 185.37 329
11401153 4х6,0 15.9 222.23 363
11401154 5х6,0 17.1 277.50 468