КОРкЕНк FRHF FE180/Eк90 (SL-НХ(St)Н FE180) Control cable, shielded, fireproof

КОРкЕНк FRHF FE180/Eк90 (SL-НХ(St)Н FE180)
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • For stationary installation in automatic control and monitoring systems of power circuits
  • In rooms with dry or humid environments under normal mechanical loads

ADVANTAGES

  • The cables are tested for installation outside the hermetic zone in cable structures and NPP premises in systems of classes: 2, 3, 4 according to the classification of NP 306.2.141-2008
  • Preservation of circuit integrity, under standard temperature conditions, from 30 to 90 minutes at temperatures from ~842˚C (Ek30) to ~1006˚C (Ek90)
  • The screen provides protection against electromagnetic waves

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

Organosilicon rubber

Outer shell

Orange halogen-free polymer composition

Number of cores

4, 5, 7, 10, 14, 19, 27, 37÷61

Screen

Synthetic film foiled with aluminum + grounding conductor.

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the rated area cross-section of the conductor, not more:

mm²
Ohm/km

0,5
36

1,0
18,1

1,5
12,1

2,5
7,41

Temperature range

-50˚С to +70˚С

Test voltage

2500 W

Operating voltage

300/500 W

Electrical resistance of insulation

20 MOhm/km

Minimum bending radius

15 х D

Color identification of cores

EN 50334

COMPLIANCE / STANDARDS

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Toxicity - p. 4.3 DSTU 4809.

Smoke smoke - clause 4.4 of DSTU 4809.

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.

Standard temperature conditions (clause 4.7 of DSTU 4809).

Integrity of circuits under conditions of exposure to flame with a temperature of at least 750 ° C - clause 4.6 of which is at least 750 ° C - 4.8 DSTU 4809, DSTU IEC 60331-21

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
11401201 2х0,5 7.6 10.33 49
11401202 3х0,5 8.0 14.94 60
11401203 4х0,5 8.7 19.54 72
11401204 5х0,5 10.0 24.15 97
11401205 7х0,5 10.8 33.36 120
11401206 10х0,5 13.4 47.18 162
11401207 14х0,5 14.4 65.61 205
11401208 19х0,5 15.9 88.64 259
11401209 27х0,5 18.9 125.49 348
11401210 37х0,5 21.5 171.55 470
11401211 2х0,75 8.3 14.94 59
11401212 3х0,75 8.7 21.85 73
11401213 4х0,75 10.0 28.76 102
11401214 5х0,75 10.8 35.67 120
11401215 7х0,75 11.7 49.48 150
11401216 10х0,75 14.6 70.21 205
11401217 14х0,75 15.8 97.85 261
11401218 19х0,75 17.5 132.40 333
11401219 27х0,75 21.3 187.68 471
11401220 37х0,75 23.7 256.77 612
11401221 2х1,0 8.8 19.54 69
11401222 3х1,0 9.9 28.76 100
11401223 4х1,0 10.7 37.97 121
11401224 5х1,0 11.6 47.18 143
11401225 7х1,0 12.6 65.61 180
11401226 10х1,0 15.7 93.25 247
11401227 14х1,0 17.0 130.10 319
11401228 19х1,0 18.9 176.16 409
11401229 27х1,0 23.0 249.86 579
11401230 37х1,0 25.7 341.99 756
11401231 2х1,5 10.0 28.76 97
11401232 3х1,5 10.6 42.57 122
11401233 4х1,5 11.5 56.39 149
11401234 5х1,5 12.5 70.21 177
11401235 7х1,5 13.5 97.85 227
11401236 10х1,5 17.0 139.31 313
11401237 14х1,5 18.5 194.59 409
11401238 19х1,5 21.0 263.68 548
11401239 27х1,5 25.0 374.24 750
11401240 37х1,5 28.4 512.43 1012
11401241 2х2,5 11.3 47.18 124
11401242 3х2,5 11.9 70.21 160
11401243 4х2,5 13.0 93.25 199
11401244 5х2,5 14.2 116.28 238
11401245 7х2,5 15.4 162.34 310
11401246 10х2,5 19.6 231.44 432
11401247 14х2,5 21.7 323.57 589
11401248 19х2,5 26.0 438.73 767
11401249 27х2,5 29.3 622.98 1083
11401250 37х2,5 32.8 853.30 1432
11401251 4х4,0 14.5 148.52 273
11401252 5х4,0 15.9 185.37 329
11401253 4х6,0 15.9 222.23 363
11401254 5х6,0 17.1 277.50 468