Аlay-net U/UTP FR Cat 5 Network cable, twisted pair, fire resistant
Stability during single burning
Stability when burning in a bundle
Halogen-free
FIELD OF APPLICATION
- At facilities with increased fire protection requirements
- For construction of structured cable systems
- Data transfer at speeds up to 100 Mbps
- ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T
ADVANTAGES
- The cables are tested for installation outside the hermetic zone in cable structures and NPP premises in systems of classes: 2, 3, 4 according to the classification of NP 306.2.141-2008
- Preservation of circuit integrity, under standard temperature conditions for 30 minutes at temperatures from ~842˚C (Ek30)
- Data transmission in fire conditions up to 30 minutes
CONSTRUCTION
|
Resin |
Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1 |
|
Insulation |
Organosilicon rubber |
|
Outer shell |
Orange halogen-free polymer composition |
|
Number of cores |
2х2, 4х2 |
TECHNICAL CHARACTERISTICS
Electrical resistance depending on the nominal diameter of the core, not more than:
mm
Ohm/km
0,51 (24 AWG)
96
|
Temperature range |
-10˚C to +70˚C |
||||||||||||||||||
|
Test voltage |
2500 W |
||||||||||||||||||
|
Operating voltage |
72 W |
||||||||||||||||||
|
Electrical resistance of insulation |
5 Gohm/km |
||||||||||||||||||
|
Minimum bending radius |
10 х D |
||||||||||||||||||
|
Color identification of cores |
DSTU IEC 61156-1 |
||||||||||||||||||
|
Signal transmission characteristics
|
|||||||||||||||||||
|
Electrical capacity |
56 pF/m |
||||||||||||||||||
|
Wave impedance in the frequency range of 1-100 MHz |
100±15 Ом |
||||||||||||||||||
COMPLIANCE / STANDARDS
DSTU ISO/IEC 11801
DSTU IEC 61156-2
Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2
Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22
Smoke smoke - clause 4.4 of DSTU 4809
Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2
Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.
Standard temperature conditions (clause 4.7 of DSTU 4809).
Integrity of circuits under conditions of exposure to flame, the temperature of which is not less than 750 ° C of which is not less than 750 ° C - 4.8 DSTU 4809, DSTU IEC 60331-23
TABLE OF NOMENCLATURES
| Article no. | Number of cores and cross section mm2 |
Maximum outer diameter |
Mass of copper | Mass. |
|---|---|---|---|---|
| 10201001 | 2х2х0,51 | 8,0 | 7,41 | 39 |
| 10201002 | 4х2х0,51 | 9,5 | 14,82 | 61 |