catalog

Аlay-net F/UTP FR Cat 5 Network cable, shielded, twisted pair, fire resistant

Аlay-net F/UTP FR Cat 5
icon_red_1

Stability during single burning

icon_red_2

Stability when burning in a bundle

icon_red_3

Halogen-free

icon_red_5

Resistant to electrical influences-shielded

FIELD OF APPLICATION

  • At facilities with increased fire protection requirements
  • For construction of structured cable systems
  • Data transfer at speeds up to 100 Mbps
  • ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T

ADVANTAGES

  • The cables are tested for installation outside the hermetic zone in cable structures and NPP premises in systems of classes: 2, 3, 4 according to the classification of NP 306.2.141-2008
  • Preservation of circuit integrity, under standard temperature conditions for 30 minutes at temperatures from ~842˚C (Ek30)
  • Data transmission in fire conditions up to 30 minutes
  • Shields protect against interference and ensure reliable signal transmission

CONSTRUCTION

Resin

Copper conductors, in accordance with the requirements of DSTU EN 60228, flexibility class 1

Insulation

Organosilicon rubber

Outer shell

Halogen-free composition in orange color

Number of cores

2х2, 4х2

Screen

Synthetic film foiled with aluminum + grounding conductor

TECHNICAL CHARACTERISTICS

Electrical resistance depending on the nominal diameter of the core, not more than:

mm
Ohm/km

0,51 (24 AWG)
96

Temperature range

-10˚C to +70˚C

Test voltage

2500 W

Operating voltage

72 W

Electrical resistance of insulation

5 Gohm/km

Minimum bending radius

10 х D

Color identification of cores

DSTU IEC 61156-1

icon

Signal transmission characteristics

Frequency, MHz 1 4 10 16 20 31,25 62,5 100
Fading 2,1 4,1 6,5 8,3 9,3 11,7 17 22

Electrical capacity

56 pF/m

Wave impedance in the frequency range of 1-100 MHz

100±15 Ом

COMPLIANCE / STANDARDS

DSTU ISO/IEC 11801

DSTU IEC 61156-2

Single combustion - clause 4.1 of DSTU 4809, DSTU EN 60332-1 -2

Combustion in bundles - clause 4.2 of DSTU 4809, DSTU EN 60332-3-22

Smoke smoke - clause 4.4 of DSTU 4809

Combustion smoke - clause 4.5 of DSTU 4809, DSTU EN 61034-2.

Halogens and corrosivity - clause 4.6 of DSTU 4809, DSTU EN 60754-2.

Standard temperature conditions (clause 4.7 of DSTU 4809).

Integrity of circuits under conditions of exposure to flame, the temperature of which is not less than 750 ° C of which is not less than 750 ° C - 4.8 DSTU 4809, DSTU IEC 60331-23

TABLE OF NOMENCLATURES

Article no. Number of cores and
cross section mm2
Maximum
outer diameter
Mass of copper Mass.
10201101 2х2х0,51 8,4 8,53 48
10201102 4х2х0,51 9,8 15,94 71